5JR5

RHCC in Complex with Elemental Sulfur

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2012-07-04
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.54192
Spacegroup nameP 31 2 1
Unit cell lengths110.520, 110.520, 71.040
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution25.751 - 1.900
R-factor0.185
Rwork0.182
R-free0.20660
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1fe6
RMSD bond length0.011
RMSD bond angle1.107
Data reduction softwareiMOSFLM
Data scaling softwareSCALA
Phasing softwareREFMAC
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 Overall
Low resolution limit [Å]25.751
High resolution limit [Å]1.900
Number of reflections39292
<I/σ(I)>6.2
Completeness [%]98.9
Redundancy4.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP82771.6M ammonium sulfate and 100 mM Tris pH 8.0

222926

PDB entries from 2024-07-24