Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5J7E

hEAG PAS domain

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]277
Detector technologyCCD
Collection date2009-12-16
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.9796
Spacegroup nameC 1 2 1
Unit cell lengths213.974, 39.058, 106.802
Unit cell angles90.00, 118.03, 90.00
Refinement procedure
Resolution29.130 - 1.900
R-factor0.214
Rwork0.214
R-free0.23100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2z6c
RMSD bond length0.005
RMSD bond angle1.200
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwareCNS (1.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.973
High resolution limit [Å]1.9001.905
Number of reflections59648
<I/σ(I)>4.14
Completeness [%]96.4
Redundancy1.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529120 mM Tris-HCl, 200 mM NaCl, 5 mM DTT

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon