5IX0
HDAC2 WITH LIGAND BRD7232
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2013-11-18 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 92.195, 97.473, 139.254 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.736 - 1.720 |
| R-factor | 0.17993 |
| Rwork | 0.180 |
| R-free | 0.20040 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.395 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0135) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 79.850 | 1.760 |
| High resolution limit [Å] | 1.720 | 1.720 |
| Rmerge | 0.080 | 0.934 |
| Number of reflections | 133389 | |
| <I/σ(I)> | 2.81 | |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 8.2 | 8.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293 | PEG 400, potassium phosphate |