5IV9
The LPS Transporter LptDE from Klebsiella pneumoniae, full-length
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 90 |
Detector technology | PIXEL |
Collection date | 2013-06-13 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.00000 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 131.219, 155.459, 197.757 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.717 - 4.369 |
R-factor | 0.3035 |
Rwork | 0.301 |
R-free | 0.34370 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.631 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 44.717 |
High resolution limit [Å] | 4.369 |
Rmerge | 0.099 |
Number of reflections | 12420 |
<I/σ(I)> | 14.3 |
Completeness [%] | 95.6 |
Redundancy | 5.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.2 | 294 | 25% 1,2-propanediol, 100 mM phosphate-citrate pH 4.2, 10% glycerol, 5% PEG 3000 |