5I7G
Metal free Glucose Isomerase collected at room temperature using the HC1b humidity controller
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 295 |
Detector technology | PIXEL |
Collection date | 2014-10-17 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.9795 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 93.815, 99.698, 102.755 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 51.378 - 1.210 |
R-factor | 0.1383 |
Rwork | 0.137 |
R-free | 0.16170 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.016 |
RMSD bond angle | 1.606 |
Data reduction software | DIALS |
Data scaling software | DIALS |
Phasing software | PH |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 69.280 | 1.240 |
High resolution limit [Å] | 1.210 | 1.210 |
Rmerge | 0.121 | 1.680 |
Number of reflections | 145645 | |
<I/σ(I)> | 6 | 1 |
Completeness [%] | 99.8 | 99.2 |
Redundancy | 6.5 | 6.5 |
CC(1/2) | 0.992 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 10 mM Hepes pH 7.5, 1.6 M Ammonium Sulphate |