Full length Open-form Sodium Channel NavMs I218C
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SOLEIL BEAMLINE PROXIMA 2 |
| Synchrotron site | SOLEIL |
| Beamline | PROXIMA 2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-11-08 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.97718 |
| Spacegroup name | I 4 2 2 |
| Unit cell lengths | 109.580, 109.580, 209.710 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 26.920 - 2.600 |
| R-factor | 0.1936 |
| Rwork | 0.193 |
| R-free | 0.21390 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3rvy |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.050 |
| Data reduction software | XDS (Oct 15, 2015) |
| Data scaling software | XDS (Oct 15, 2015) |
| Phasing software | PHASER (2.5.7) |
| Refinement software | BUSTER (2.10.2) |
Data quality characteristics
| Outer shell | |
| Low resolution limit [Å] | 2.720 |
| High resolution limit [Å] | 2.600 |
| Rmerge | 3.600 |
| <I/σ(I)> | 1.4 |
| Completeness [%] | 99.7 |
| Redundancy | 45.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 277 | 0.05 M NaCl, 0.1 M MES buffer, pH 6.5, 37.8% v/v polyethylene glycol (PEG) 400 and 4% ethylene glycol |