5HV2
Rifampin phosphotransferase G527Y mutant from Listeria monocytogenes
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 77 |
Detector technology | IMAGE PLATE |
Collection date | 2015-04-15 |
Detector | MAR555 FLAT PANEL |
Wavelength(s) | 0.979 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 58.751, 128.760, 142.392 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.397 - 2.912 |
R-factor | 0.2168 |
Rwork | 0.212 |
R-free | 0.26850 |
RMSD bond length | 0.011 |
RMSD bond angle | 1.503 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.900 |
Number of reflections | 24022 |
<I/σ(I)> | 14.9 |
Completeness [%] | 99.1 |
Redundancy | 4.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 8.4 | 277 | 19%(w/v) PEG8000, 100 mM Tris-HCl, 200 mM lithium chloride |