5HNL
In-house X-ray single crystal diffraction from protein microcrystals via magnetically oriented microcrystal arrays in gels
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 293 |
Detector technology | IMAGE PLATE |
Collection date | 2014-05-07 |
Detector | RIGAKU RAXIS VII |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 30.530, 56.420, 73.340 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.746 - 2.424 |
R-factor | 0.1723 |
Rwork | 0.171 |
R-free | 0.18770 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.622 |
Data reduction software | iMOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.10_2155) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 56.420 |
High resolution limit [Å] | 2.420 |
Number of reflections | 4958 |
<I/σ(I)> | 6.9 |
Completeness [%] | 96.8 |
Redundancy | 4.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH MODE | 313 | PEG 4000, Sodium chloride |