5HEH
Pentameric ligand-gated ion channel GLIC mutant P246A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-02-28 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9197 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 177.690, 133.940, 159.830 |
Unit cell angles | 90.00, 101.10, 90.00 |
Refinement procedure
Resolution | 29.913 - 3.300 |
R-factor | 0.2457 |
Rwork | 0.244 |
R-free | 0.28030 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3ehz |
RMSD bond length | 0.003 |
RMSD bond angle | 0.654 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.400 |
High resolution limit [Å] | 3.300 | 3.300 |
Rmerge | 0.101 | 0.773 |
Number of reflections | 55197 | |
<I/σ(I)> | 13.1 | 2.4 |
Completeness [%] | 99.6 | 99.6 |
Redundancy | 5.3 | 5.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4 | 277 | PEG 4000, Ammonium Sulfate |