Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5HEG

Pentameric ligand-gated ion channel GLIC mutant P246G

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2012-02-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.920
Spacegroup nameC 1 2 1
Unit cell lengths180.380, 134.210, 160.790
Unit cell angles90.00, 101.97, 90.00
Refinement procedure
Resolution29.924 - 3.214
R-factor0.2476
Rwork0.247
R-free0.25780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ehz
RMSD bond length0.004
RMSD bond angle0.777
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.10_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.300
High resolution limit [Å]3.2003.200
Rmerge0.1220.956
Number of reflections60901
<I/σ(I)>9.39.3
Completeness [%]98.382.8
Redundancy4.44.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4277Ammonium sulfate, PEG 4000

227111