5HB0
Crystal structure of Chaetomium thermophilum Nup170 CTD-Nup145N complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-02-19 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0332 |
Spacegroup name | P 1 |
Unit cell lengths | 75.590, 111.470, 111.750 |
Unit cell angles | 91.82, 92.47, 91.36 |
Refinement procedure
Resolution | 45.364 - 3.500 |
R-factor | 0.2124 |
Rwork | 0.210 |
R-free | 0.26000 |
RMSD bond length | 0.005 |
RMSD bond angle | 0.616 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 3.500 |
Number of reflections | 45493 |
<I/σ(I)> | 6.2 |
Completeness [%] | 98.8 |
Redundancy | 7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 294 | 12 % (w/v) PEG 3350, 0.2 M lithium acetate |