5HAZ
Structure of Chaetomium thermophilum Nup170 CTD
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-11-25 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.0332 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 141.260, 54.770, 108.200 |
Unit cell angles | 90.00, 91.05, 90.00 |
Refinement procedure
Resolution | 37.255 - 2.100 |
R-factor | 0.2068 |
Rwork | 0.206 |
R-free | 0.23060 |
RMSD bond length | 0.005 |
RMSD bond angle | 0.626 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.100 |
Number of reflections | 47908 |
<I/σ(I)> | 21 |
Completeness [%] | 97.8 |
Redundancy | 6.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 294 | 0.1 M HEPES (pH 7.0), 1.0 M sodium acetate |