Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 12.3.1 |
Synchrotron site | ALS |
Beamline | 12.3.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-03-11 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97888 |
Spacegroup name | P 31 |
Unit cell lengths | 48.648, 48.648, 118.090 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 24.324 - 2.122 |
R-factor | 0.2295 |
Rwork | 0.223 |
R-free | 0.25900 |
RMSD bond length | 0.008 |
RMSD bond angle | 1.098 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.7.3_928) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 2.120 |
Number of reflections | 17702 |
<I/σ(I)> | 18 |
Completeness [%] | 98.0 |
Redundancy | 3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 298 | 100mM Tris pH 7.0, 20% PEG 3350 MME |