5GXW
Importin and NuMA complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2016-09-18 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 78.065, 89.658, 101.187 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.822 - 2.394 |
R-factor | 0.1859 |
Rwork | 0.183 |
R-free | 0.21830 |
RMSD bond length | 0.009 |
RMSD bond angle | 0.989 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Number of reflections | 28006 | 2392 |
<I/σ(I)> | 29.9 | 4.3 |
Completeness [%] | 98.3 | 85.1 |
Redundancy | 5.8 | 4.3 |
CC(1/2) | 0.833 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 1M KCl, 0.8M ammonium sulfate, 100mM Hepes, pH 7.0 |