Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5GXW

Importin and NuMA complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2016-09-18
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths78.065, 89.658, 101.187
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.822 - 2.394
R-factor0.1859
Rwork0.183
R-free0.21830
RMSD bond length0.009
RMSD bond angle0.989
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.490
High resolution limit [Å]2.4002.400
Number of reflections280062392
<I/σ(I)>29.94.3
Completeness [%]98.385.1
Redundancy5.84.3
CC(1/2)0.833
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2931M KCl, 0.8M ammonium sulfate, 100mM Hepes, pH 7.0

237423

PDB entries from 2025-06-11

PDB statisticsPDBj update infoContact PDBjnumon