5GOE
Truncated mitofusin-1, GDP-bound
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-12-12 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 0.97915 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 70.420, 72.910, 94.970 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.693 - 1.801 |
R-factor | 0.1784 |
Rwork | 0.177 |
R-free | 0.20420 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.763 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 44.700 |
High resolution limit [Å] | 1.800 |
Number of reflections | 86503 |
<I/σ(I)> | 25.08 |
Completeness [%] | 98.9 |
Redundancy | 7.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2M ammonium citrate tribasic and 20% PEG 3350 |