5GNH
Myotubularin-related protein 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
Synchrotron site | PAL/PLS |
Beamline | 7A (6B, 6C1) |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-02-12 |
Detector | ADSC QUANTUM 270 |
Wavelength(s) | 1.000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 158.344, 82.820, 99.972 |
Unit cell angles | 90.00, 117.59, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.600 |
R-factor | 0.20574 |
Rwork | 0.203 |
R-free | 0.25760 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.460 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0135) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.600 |
Number of reflections | 33545 |
<I/σ(I)> | 15.68 |
Completeness [%] | 95.3 |
Redundancy | 4.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 295 | 100mM HEPES pH 7.5, 10% (v/v) polyethylene glycol 6000 |