5GGR

PD-1 in complex with nivolumab Fab

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPAL/PLS BEAMLINE 7A (6B, 6C1)
Synchrotron sitePAL/PLS
Beamline7A (6B, 6C1)
Temperature [K]100
Detector technologyCCD
Collection date2015-06-05
DetectorADSC QUANTUM 270
Wavelength(s)1
Spacegroup nameP 1 21 1
Unit cell lengths91.290, 48.612, 134.904
Unit cell angles90.00, 102.12, 90.00
Refinement procedure
Resolution29.752 - 3.300
R-factor0.2239
Rwork0.222
R-free0.26790
RMSD bond length0.007
RMSD bond angle1.286
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]3.300
Number of reflections17556
<I/σ(I)>6.9
Completeness [%]99.0
Redundancy3.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293100 mM MES, pH 6.5, 12% PEG500 MME, 6% PEG20,000, 50 mM ammonium acetate

245663

PDB entries from 2025-12-03