5G0V
InhA in complex with a DNA encoded library hit
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-05-21 |
Detector | DECTRIS PILATUS |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 65.151, 111.727, 67.813 |
Unit cell angles | 90.00, 98.30, 90.00 |
Refinement procedure
Resolution | 57.530 - 1.790 |
R-factor | 0.1606 |
Rwork | 0.159 |
R-free | 0.18820 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4d0r |
RMSD bond length | 0.010 |
RMSD bond angle | 0.990 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | AMoRE |
Refinement software | BUSTER (2.11.5) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 57.500 | 2.070 |
High resolution limit [Å] | 1.790 | 1.790 |
Rmerge | 0.060 | 0.340 |
Number of reflections | 88619 | |
<I/σ(I)> | 13.3 | 3.4 |
Completeness [%] | 98.0 | 99 |
Redundancy | 3.5 | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.2 | pH 7.2 |