Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5FA7

CTX-M-15 in complex with FPI-1523

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2015-07-15
DetectorRAYONIX MX-300
Wavelength(s)1.00
Spacegroup nameP 1 21 1
Unit cell lengths62.730, 60.270, 76.010
Unit cell angles90.00, 112.78, 90.00
Refinement procedure
Resolution33.400 - 1.670
R-factor0.1767
Rwork0.175
R-free0.20650
RMSD bond length0.010
RMSD bond angle1.120
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.0)
Data quality characteristics
 Overall
Low resolution limit [Å]70.100
High resolution limit [Å]1.670
Number of reflections59836
<I/σ(I)>12.2
Completeness [%]98.4
Redundancy2.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.52980.2M ammonium sulfate, 0.1M MES pH6.5, 30% PEG5K monomethyl ether

218853