5F8E
Rv2258c-SAH
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
| Synchrotron site | PAL/PLS |
| Beamline | 7A (6B, 6C1) |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-06-20 |
| Detector | ADSC QUANTUM 270 |
| Wavelength(s) | 1.00000 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 110.012, 140.444, 96.993 |
| Unit cell angles | 90.00, 98.31, 90.00 |
Refinement procedure
| Resolution | 50.000 - 2.900 |
| R-factor | 0.2042 |
| Rwork | 0.201 |
| R-free | 0.26960 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.439 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | REFMAC (5.8.0124) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.950 |
| High resolution limit [Å] | 2.900 | 2.900 |
| Number of reflections | 32186 | |
| <I/σ(I)> | 10.9 | 2.8 |
| Completeness [%] | 99.9 | |
| Redundancy | 4.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 296 | sodium malonate, PEG 3350 |