5F4U
HIV-1 gp120 complex with BNM-IV-197
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 180 |
Detector technology | CCD |
Collection date | 2015-10-12 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9792 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 67.439, 128.123, 193.599 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.400 - 3.100 |
R-factor | 0.2208 |
Rwork | 0.218 |
R-free | 0.27990 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3tgr |
RMSD bond length | 0.005 |
RMSD bond angle | 1.175 |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.4_1496) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 48.400 |
High resolution limit [Å] | 3.100 |
Rmerge | 0.133 |
Number of reflections | 15645 |
<I/σ(I)> | 9 |
Completeness [%] | 99.9 |
Redundancy | 5.88 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 290 | peg 1500,calcium chloride, imidazole |