5F4L

HIV-1 gp120 complex with JP-III-048

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBSRF BEAMLINE 1W2B
Synchrotron siteBSRF
Beamline1W2B
Temperature [K]170
Detector technologyCCD
Collection date2014-04-02
DetectorAPEX II CCD
Wavelength(s)0.9791
Spacegroup nameC 2 2 21
Unit cell lengths67.159, 127.806, 192.470
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.439 - 2.700
R-factor0.2503
Rwork0.248
R-free0.28810
RMSD bond length0.004
RMSD bond angle0.811
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 Overall
Low resolution limit [Å]45.276
High resolution limit [Å]2.700
Rmerge0.119
Number of reflections23229
<I/σ(I)>12.5
Completeness [%]99.9
Redundancy10.88
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION290PEG 1500, magnesium chloride, imidazole

226707