5F22
C-terminal domain of SARS-CoV nsp8 complex with nsp7
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-05-04 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.977 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 50.862, 71.439, 115.383 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.719 - 2.155 |
R-factor | 0.216 |
Rwork | 0.212 |
R-free | 0.25230 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.020 |
RMSD bond angle | 1.302 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.7_650) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 1.600 |
Number of reflections | 11223 |
<I/σ(I)> | 59.3 |
Completeness [%] | 100.0 |
Redundancy | 18.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289 | 0.2M magnesium acetate, PEG 3350 |