Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5EZ9

A de novo designed heptameric coiled coil CC-Hept-I-H-I

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]90
Detector technologyPIXEL
Collection date2014-08-14
DetectorPSI PILATUS 6M
Wavelength(s)0.980
Spacegroup nameI 1 2 1
Unit cell lengths62.400, 63.030, 70.122
Unit cell angles90.00, 108.40, 90.00
Refinement procedure
Resolution43.150 - 1.800
R-factor0.177
Rwork0.175
R-free0.21660
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4pna
RMSD bond length0.008
RMSD bond angle0.849
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.1501.840
High resolution limit [Å]1.8001.800
Rmerge0.1340.343
Number of reflections23051
<I/σ(I)>5.12.7
Completeness [%]96.395.4
Redundancy2.82.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52920.2 M MgSO4, 0.1 M Tris at ph 8.5 with 3.4 M 1,6-hexanediol

222036

PDB entries from 2024-07-03

PDB statisticsPDBj update infoContact PDBjnumon