Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5EYL

TUBULIN-BINDING DARPIN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-3
Synchrotron siteESRF
BeamlineMASSIF-3
Temperature [K]100
Detector technologyPIXEL
Collection date2015-07-28
DetectorDECTRIS EIGER X 4M
Wavelength(s)0.9677
Spacegroup nameH 3 2
Unit cell lengths105.311, 105.311, 192.962
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.380 - 2.410
R-factor0.1758
Rwork0.174
R-free0.21890
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dui
RMSD bond length0.010
RMSD bond angle1.210
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]52.7002.500
High resolution limit [Å]2.4102.410
Rmerge0.134
Number of reflections16124
<I/σ(I)>10.41.6
Completeness [%]99.490
Redundancy6.76.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.6293sodium acetate, sodium formate

222036

PDB entries from 2024-07-03