Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5ERQ

Gephyrin E domain at 1.55 angstrom resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2014-11-25
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9762
Spacegroup nameI 2 2 2
Unit cell lengths87.669, 99.287, 113.725
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.383 - 1.550
R-factor0.1557
Rwork0.154
R-free0.18700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4pd0
RMSD bond length0.010
RMSD bond angle1.334
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.0001.580
High resolution limit [Å]1.5501.550
Rmerge0.0550.808
Number of reflections71703
<I/σ(I)>11.11.5
Completeness [%]98.898.2
Redundancy3.73.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.52930.1 M sodium acetate, 25% MPD

221716

PDB entries from 2024-06-26

PDB statisticsPDBj update infoContact PDBjnumon