5EOF
Crystal structure of OPTN NTD and TBK1 CTD complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 298.15 |
Detector technology | CCD |
Collection date | 2015-06-25 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9791 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 36.321, 54.775, 153.141 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 37.344 - 2.050 |
R-factor | 0.2094 |
Rwork | 0.207 |
R-free | 0.24540 |
RMSD bond length | 0.007 |
RMSD bond angle | 0.960 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.8.2_1309) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.050 |
Number of reflections | 19991 |
<I/σ(I)> | 14.85 |
Completeness [%] | 99.9 |
Redundancy | 6.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 291.15 | 0.1M MES monohydrate pH 6.0, 14% w/v polyethylene glycol 4000 |