5E8V
TGF-BETA RECEPTOR TYPE 2 KINASE DOMAIN (E431A,R433A,E485A,K488A,R493A,R495A)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-10-30 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 60.920, 76.310, 78.120 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 24.740 - 1.690 |
R-factor | 0.1939 |
Rwork | 0.193 |
R-free | 0.21940 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3tzm |
RMSD bond length | 0.010 |
RMSD bond angle | 1.070 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER-TNT (BUSTER 2.11.6) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.040 | 1.950 |
High resolution limit [Å] | 1.690 | 1.690 |
Rmerge | 0.338 | |
Number of reflections | 40664 | |
<I/σ(I)> | 19 | 4.1 |
Completeness [%] | 98.7 | 97.9 |
Redundancy | 6.6 | 6.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 277 | 100 mm TRIS-HCl, PH 8.5, 150 mm MgCl2, 24%(w/v) PEG4000, 20%(v/v) glcyerol |