5DUR
Influenza A virus H5 hemagglutinin globular head in complex with antibody 100F4
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-04-26 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 88.094, 101.223, 206.301 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.500 - 2.820 |
R-factor | 0.2101 |
Rwork | 0.208 |
R-free | 0.25710 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.385 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 40.500 |
High resolution limit [Å] | 2.820 |
Number of reflections | 45011 |
<I/σ(I)> | 10.5 |
Completeness [%] | 99.8 |
Redundancy | 4.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 9 | 291 | 4.0M Potassium formate, Tris propane PH 9.0, 2% w/v PEGME 2000 |