Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5DJ2

Fc Heterodimer Design 7.4 Y407A + T366V/K409V

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]193
Detector technologyCCD
Collection date2013-09-26
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.97949
Spacegroup nameP 1 21 1
Unit cell lengths60.394, 67.242, 78.766
Unit cell angles90.00, 104.89, 90.00
Refinement procedure
Resolution30.000 - 2.560
R-factor0.19034
Rwork0.187
R-free0.24307
RMSD bond length0.007
RMSD bond angle1.228
Data scaling softwareSCALA (3.3.20)
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0017)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]30.00067.2422.700
High resolution limit [Å]2.5608.1002.560
Rmerge0.0410.467
Rmeas0.131
Rpim0.0680.0280.314
Total number of observations72742219410808
Number of reflections19661
<I/σ(I)>8.918.92.3
Completeness [%]99.095.9100
Redundancy3.73.43.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION29417% PEG 3350 + 100mM Magnesium Formate dihydrate

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon