HIV-1 Rev NTD dimers with variable crossing angles

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]80
Detector technologyPIXEL
Collection date2010-07-01
DetectorPSI PILATUS 6M
Wavelength(s)0.9793
Spacegroup nameP 21 21 21
Unit cell lengths44.528, 87.101, 166.669
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.840 - 2.900
R-factor0.2473
Rwork0.246
R-free0.27320
RMSD bond length0.010
RMSD bond angle1.210
Refinement softwareBUSTER (2.9.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.000
High resolution limit [Å]2.9002.900
Number of reflections14917
<I/σ(I)>10.31.1
Completeness [%]99.599.2
Redundancy13.313.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293Crystals of scFv-Rev were initially grown in 20% PEG 3350, a variety of salts (200 mM sodium sulfate, sodium bromide, or ammonium phosphate dibasic), and pH ranging from 6.5-8.5