Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5D2A

Bifunctional dendrimers

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]100
Detector technologyPIXEL
Collection date2014-12-19
DetectorDECTRIS PILATUS 2M-F
Wavelength(s)1.0000
Spacegroup nameP 63 2 2
Unit cell lengths105.107, 105.107, 111.092
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.506 - 2.134
R-factor0.2091
Rwork0.205
R-free0.24600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4ce8
RMSD bond length0.010
RMSD bond angle1.320
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 Overall
Low resolution limit [Å]47.506
High resolution limit [Å]2.130
Number of reflections38033
<I/σ(I)>14.95
Completeness [%]99.5
Redundancy10.28
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.52922M sodium chloride

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon