5CT7
BRAF in Complex with RAF265
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-11-09 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.000 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 109.380, 109.380, 158.130 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.910 - 3.170 |
R-factor | 0.1829 |
Rwork | 0.181 |
R-free | 0.21730 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.130 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.4) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.910 | 3.290 |
High resolution limit [Å] | 3.170 | 3.170 |
Rmerge | 0.118 | 0.720 |
Number of reflections | 16841 | |
<I/σ(I)> | 17 | 2.8 |
Completeness [%] | 99.9 | 99.9 |
Redundancy | 7 | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.4 | 277 | 12% PEG8000, 0.1 M NaCl, and 0.1 M Tris pH 8.4 |