Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5C7U

5'-monophosphate wt Guanine Riboswitch bound to hypoxanthine.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2014-03-22
DetectorPSI PILATUS 6M
Wavelength(s)0.979
Spacegroup nameP 65 2 2
Unit cell lengths52.600, 52.600, 278.120
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.553 - 3.050
R-factor0.2034
Rwork0.201
R-free0.24110
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4fe5
RMSD bond length0.008
RMSD bond angle1.663
Data reduction softwareHKL-2000
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (dev_1405)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.3603.160
High resolution limit [Å]3.0503.050
Rmerge0.0650.500
Number of reflections4923
<I/σ(I)>335.1
Completeness [%]100.0100
Redundancy1414.82
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.529617% PEG 1000; 240 mM NH4OAc; 10 mM K-HEPES; 10 mM Co(NH3)6Cl3

227111