5C6P
protein C
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-07-01 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 1 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 117.642, 117.642, 225.989 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 20.000 - 3.000 |
Rwork | 0.280 |
R-free | 0.29000 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHARP |
Refinement software | REFMAC |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 100.000 |
High resolution limit [Å] | 3.000 |
Number of reflections | 33124 |
<I/σ(I)> | 20 |
Completeness [%] | 91.0 |
Redundancy | 6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | PEG400 |