Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5C6N

protein A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2013-07-01
DetectorMAR CCD 165 mm
Wavelength(s)1
Spacegroup nameP 21 21 21
Unit cell lengths89.678, 93.418, 101.786
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 3.000
Rwork0.280
R-free0.30000
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSHARP
Refinement softwareREFMAC
Data quality characteristics
 Overall
Low resolution limit [Å]100.000
High resolution limit [Å]3.000
Number of reflections15805
<I/σ(I)>20.2
Completeness [%]90.0
Redundancy9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION293PEG

220113

PDB entries from 2024-05-22