5Y56
Fc mutant (K392D/K409D/D399K)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL19U1 |
Synchrotron site | SSRF |
Beamline | BL19U1 |
Temperature [K] | 80 |
Detector technology | CCD |
Collection date | 2013-05-02 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.987 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 65.130, 65.130, 477.521 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 36.445 - 2.653 |
R-factor | 0.264 |
Rwork | 0.260 |
R-free | 0.29770 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1dn2 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.176 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 48.570 |
High resolution limit [Å] | 2.650 |
Number of reflections | 18054 |
<I/σ(I)> | 50.6 |
Completeness [%] | 95.2 |
Redundancy | 13.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 1.5M (NH4)2SO4, 10% Glycerol, 0.1M Tris-Hcl (pH 7.5) |