Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5XZG

Mouse cGAS bound to the inhibitor RU521

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]77
Detector technologyPIXEL
Collection date2016-12-08
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.979
Spacegroup nameI 2 2 2
Unit cell lengths85.562, 98.430, 130.372
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.215 - 1.828
R-factor0.1958
Rwork0.194
R-free0.23170
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.153
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.215
High resolution limit [Å]1.8281.828
Number of reflections45239
<I/σ(I)>17.7
Completeness [%]92.3
Redundancy4.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.1 M MES, pH 6.9, 22.5% PEG400, 0.08 M magnesium chloride

219869