5WHB
KRas G12V, bound to GDP and miniprotein 225-11(A30R)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-04-21 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97918 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 41.002, 232.043, 47.924 |
Unit cell angles | 90.00, 90.10, 90.00 |
Refinement procedure
Resolution | 116.000 - 2.180 |
R-factor | 0.207 |
Rwork | 0.205 |
R-free | 0.25200 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3GF3GFTT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.460 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHENIX (1.9_1692) |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 116.000 | 2.240 |
High resolution limit [Å] | 2.180 | 2.180 |
Rmerge | 0.097 | |
Number of reflections | 44361 | |
<I/σ(I)> | 7.9 | |
Completeness [%] | 95.3 | |
Redundancy | 2.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 0.25M CALCIUM CHLORIDE, 24% PEG 3350 |