5W5I
Human IFIT1 dimer with PPP-AAAA
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 94 |
| Detector technology | CCD |
| Collection date | 2015-06-16 |
| Detector | RAYONIX MX300HE |
| Wavelength(s) | 0.979 |
| Spacegroup name | I 4 |
| Unit cell lengths | 184.789, 184.789, 88.864 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 44.397 - 2.650 |
| R-factor | 0.22 |
| Rwork | 0.219 |
| R-free | 0.24160 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.002 |
| RMSD bond angle | 0.477 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.10_2142: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.700 |
| High resolution limit [Å] | 2.650 | 2.650 |
| Rpim | 0.025 | 0.383 |
| Number of reflections | 43686 | |
| <I/σ(I)> | 29.6 | 2 |
| Completeness [%] | 99.8 | 99.2 |
| Redundancy | 6.4 | 6.4 |
| CC(1/2) | 0.850 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.1 | 277.15 | 27 - 32 % PEG 200, 0.1 M Tris pH 8.1, 200 mM CaCl2 |