5VX3
Bcl-xL in complex with Bim-h3Pc-RT
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-04-21 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.9537 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 125.661, 68.811, 102.830 |
| Unit cell angles | 90.00, 125.35, 90.00 |
Refinement procedure
| Resolution | 41.936 - 1.945 |
| R-factor | 0.196 |
| Rwork | 0.194 |
| R-free | 0.24290 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.844 |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 41.936 |
| High resolution limit [Å] | 1.945 |
| Rmerge | 0.097 |
| Number of reflections | 52409 |
| <I/σ(I)> | 8.4 |
| Completeness [%] | 99.0 |
| Redundancy | 3.7 |
| CC(1/2) | 0.995 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 273 | 200 mM magnesium chloride, 20 % PEG 6000, and 100 mM sodium MES pH 6 |