5VWY
Bak core latch dimer in complex with Bim-h3Pc-RT
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-02-04 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.9537 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 65.890, 37.540, 69.560 |
| Unit cell angles | 90.00, 107.86, 90.00 |
Refinement procedure
| Resolution | 32.450 - 1.555 |
| R-factor | 0.1787 |
| Rwork | 0.175 |
| R-free | 0.21560 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.138 |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 32.450 |
| High resolution limit [Å] | 1.555 |
| Rmerge | 0.066 |
| Number of reflections | 21962 |
| <I/σ(I)> | 13.68 |
| Completeness [%] | 93.0 |
| Redundancy | 3.6 |
| CC(1/2) | 0.999 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 277 | 15.8 % PEG 8000, 50 mM potassium dihydrogen phosphate, and 22.7 % glycerol |