Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5VWW

Bak core latch dimer in complex with Bim-RT - Tetragonal

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2014-04-08
DetectorADSC QUANTUM 315r
Wavelength(s)0.9537
Spacegroup nameP 43 21 2
Unit cell lengths87.790, 87.790, 95.460
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution39.881 - 2.802
R-factor0.2301
Rwork0.225
R-free0.28110
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.003
RMSD bond angle0.424
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 Overall
Low resolution limit [Å]43.900
High resolution limit [Å]2.800
Rmerge0.120
Number of reflections9619
<I/σ(I)>19.77
Completeness [%]100.0
Redundancy14
CC(1/2)0.990
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION28112.5 % MPD (2-methyl-2,4-pentanediol), 38 mM imidazole pH 6.5, 12.5 % PEG 1000, 12.5 % PEG 3350, 30 mM sodium fluoride, 30 mM sodium iodide, 62 mM sodium MES pH 6.5 and 30 mM sodium bromide

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon