5VSH

CH1/Clambda Fab based on Pertuzumab

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]77
Detector technologyCCD
Collection date2015-04-22
DetectorRAYONIX MX225HE
Wavelength(s)0.97931
Spacegroup nameC 1 2 1
Unit cell lengths137.531, 106.207, 156.772
Unit cell angles90.00, 117.48, 90.00
Refinement procedure
Resolution25.700 - 2.550
R-factor0.209
Rwork0.206
R-free0.25520
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1l7i
RMSD bond length0.008
RMSD bond angle1.040
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.5)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.7002.690
High resolution limit [Å]2.5502.550
Rmerge0.1380.527
Number of reflections608268443
<I/σ(I)>6.52
Completeness [%]93.189.2
Redundancy3.63.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION294see publication

220113