CaV beta2a subunit: CaV1.2 AID-CAP complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]80
Detector technologyPIXEL
Collection date2012-11-19
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.11587
Spacegroup nameH 3
Unit cell lengths81.805, 81.805, 163.271
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution15.000 - 2.000
R-factor0.18676
Rwork0.184
R-free0.23021
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1t3s
RMSD bond length0.007
RMSD bond angle1.193
Data reduction softwareiMOSFLM (7.0.4)
Data scaling softwareSCALA (3.3.20)
Phasing softwarePHASER (2.5.1)
Refinement softwareREFMAC (5.8.0049)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.5002.110
High resolution limit [Å]2.0002.000
Rmerge0.1091.937
Number of reflections23913
<I/σ(I)>5.90.4
Completeness [%]86.690.1
Redundancy1.31.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.327734-37% PEG400, 0.1 M magnesium chloride, 0.1 M MES, pH 6.3

219869