5T1Y
MLA10 coiled-coil fragment
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-07-12 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9537 |
Spacegroup name | P 1 |
Unit cell lengths | 30.720, 87.140, 92.247 |
Unit cell angles | 89.93, 90.00, 89.98 |
Refinement procedure
Resolution | 40.785 - 2.050 |
R-factor | 0.2543 |
Rwork | 0.252 |
R-free | 0.27880 |
Structure solution method | SAD |
RMSD bond length | 0.001 |
RMSD bond angle | 0.348 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | CRANK2 |
Refinement software | PHENIX (dev_2376) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.120 | 2.100 |
High resolution limit [Å] | 2.050 | 2.050 |
Rmerge | 0.047 | 0.037 |
Number of reflections | 58095 | |
<I/σ(I)> | 8.2 | |
Completeness [%] | 96.5 | |
Redundancy | 1.8 | |
CC(1/2) | 0.996 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | Pact Premier, condition B4 (MIB buffer pH 7.0, 25% PEG 1500) |