Cdk2(F80C, C177A) with covalent adduct at C80

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyCCD
Collection date2017-02-16
DetectorADSC QUANTUM 315
Wavelength(s)0.9763
Spacegroup nameP 21 21 21
Unit cell lengths52.713, 71.218, 72.317
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.700 - 1.770
R-factor0.16442
Rwork0.162
R-free0.20611
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4ek3
RMSD bond length0.023
RMSD bond angle2.199
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.7401.810
High resolution limit [Å]1.7701.770
Rmerge0.0150.048
Number of reflections271881526
<I/σ(I)>31.712.6
Completeness [%]100.099.9
Redundancy1.91.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29815% w/v Jeffamine ED-2003, 50 mM HEPES, 50 mM sodium/potassium phosphate

219869