5NIT
Glucose oxidase mutant A2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR591 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2013-05-23 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 128.657, 128.657, 77.693 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 111.420 - 1.870 |
R-factor | 0.16678 |
Rwork | 0.165 |
R-free | 0.20393 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1cf3 |
RMSD bond length | 0.019 |
RMSD bond angle | 1.952 |
Data reduction software | iMOSFLM (7.2.1) |
Data scaling software | SCALA (6.5.019) |
Phasing software | PHASER (7.0.20) |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 45.270 |
High resolution limit [Å] | 1.860 |
Number of reflections | 61296 |
<I/σ(I)> | 12.6 |
Completeness [%] | 98.1 |
Redundancy | 8.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 280 | 100 mM HEPES 40% v/v dioxane |