Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5NI3

sfGFP 204-204 mutant dimer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
Collection date2016-07-07
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.979
Spacegroup nameP 21 21 21
Unit cell lengths96.700, 98.020, 102.640
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution57.170 - 1.280
R-factor0.17495
Rwork0.174
R-free0.19102
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5bt0
RMSD bond length0.026
RMSD bond angle2.264
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0189)
Data quality characteristics
 Overall
Low resolution limit [Å]57.170
High resolution limit [Å]1.280
Number of reflections249821
<I/σ(I)>17.7
Completeness [%]99.9
Redundancy7.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP291PACT condition C6: 0.1M PCTP Buffer, pH 9.0, 25% PEG 1500

245663

PDB entries from 2025-12-03

PDB statisticsPDBj update infoContact PDBjnumon