Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5MGW

Kinetic and Structural Changes in HsmtPheRS, Induced by Pathogenic Mutations in Human FARS2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]295
Detector technologyPIXEL
Collection date2016-02-19
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.97
Spacegroup nameP 21 21 21
Unit cell lengths53.355, 90.117, 99.081
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.912 - 1.460
R-factor0.1855
Rwork0.185
R-free0.20490
RMSD bond length0.006
RMSD bond angle0.820
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 Overall
Low resolution limit [Å]45.912
High resolution limit [Å]1.460
Number of reflections83388
<I/σ(I)>33.2
Completeness [%]100.0
Redundancy4.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2922 mM DTT, 100 mM bis-Tris propane pH 7 and 1.8 M sodium acetate pH 7

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon