5MGW
Kinetic and Structural Changes in HsmtPheRS, Induced by Pathogenic Mutations in Human FARS2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 295 |
Detector technology | PIXEL |
Collection date | 2016-02-19 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 53.355, 90.117, 99.081 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.912 - 1.460 |
R-factor | 0.1855 |
Rwork | 0.185 |
R-free | 0.20490 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.820 |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 45.912 |
High resolution limit [Å] | 1.460 |
Number of reflections | 83388 |
<I/σ(I)> | 33.2 |
Completeness [%] | 100.0 |
Redundancy | 4.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 292 | 2 mM DTT, 100 mM bis-Tris propane pH 7 and 1.8 M sodium acetate pH 7 |