Kinetic and Structural Changes in HsmtPheRS, Induced by Pathogenic Mutations in Human FARS2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]295
Detector technologyPIXEL
Collection date2016-02-19
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.97
Spacegroup nameP 21 21 21
Unit cell lengths53.355, 90.117, 99.081
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.912 - 1.460
R-factor0.1855
Rwork0.185
R-free0.20490
RMSD bond length0.006
RMSD bond angle0.820
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 Overall
Low resolution limit [Å]45.912
High resolution limit [Å]1.460
Number of reflections83388
<I/σ(I)>33.2
Completeness [%]100.0
Redundancy4.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2922 mM DTT, 100 mM bis-Tris propane pH 7 and 1.8 M sodium acetate pH 7